Abstract

In the topology of the DC traction substation there is a rectifier component which generally uses a 12 pulse rectifier type and the load is in the form of a trainset with a component in the form of a converter used for variable speed drives (VSD). The operation of the rectifier and the VSD converter load causes harmonics to appear on the AC input side, so anticipation needs to be done. Therefore, it is necessary to conduct an assessment related to DC traction substations to obtain good electrical power quality. The purpose of this study was to determine the electric power quality parameters of DC railway traction using a 12 pulse rectifier and a VSD converter load. This research was conducted by simulating a DC railway traction model with a 12 pulse rectifier and knowing the comparison of the system power quality between the VSD converter load and the resistive load as the basic reference for the traction substation work system of this model. System modeling is done using PSIM software. The results of the simulation are the parameters of the stability of the voltage, current, and system harmonics.

References

F. A. A. Rahman, M. Z. A. A. Kadir, M. Osman, and U. A. U. Amirulddin, “Review of the AC Overhead Wires, the DC Third Rail and the DC Fourth Rail Transit Lines: Issues and Challenges,” IEEE Access, vol. 8, pp. 213277–213295, 2020, doi: 10.1109/ACCESS.2020.3040018.

M. Popescu and A. Bitoleanu, “A Review of the Energy Efficiency Improvement in DC Railway Systems,” Energies, vol. 12, no. 6, Art. no. 6, Jan. 2019, doi: 10.3390/en12061092.

T. Zhao and M. Wu, “Electric power characteristics of all-parallel AT traction power supply system,” in Proceedings 2011 International Conference on Transportation, Mechanical, and Electrical Engineering (TMEE), ChangChun, China, Dec. 2011, pp. 895–898. doi: 10.1109/TMEE.2011.6199346.

“Fase 1 | MRT Jakarta.” https://jakartamrt.co.id/id/proyek/fase-1 (accessed Nov. 09, 2022).

M. Popescu, A. Bitoleanu, V. Suru, and M. Dobriceanu, “Increasing power quality in a 6-pulse DC-traction substation,” in 2017 International Conference on Electromechanical and Power Systems (SIELMEN), Iasi, Oct. 2017, pp. 483–488. doi: 10.1109/SIELMEN.2017.8123376.

S.-A. Kim, S.-W. Han, S.-I. Byun, and Y.-H. Cho, “Improved parallel operation mode control of parallel connected 12-pulse thyristor dual converter for urban railway power substations,” in 2016 IEEE 17th Workshop on Control and Modeling for Power Electronics (COMPEL), Trondheim, Norway, Jun. 2016, pp. 1–6. doi: 10.1109/COMPEL.2016.7556662.

F. Meng, W. Yang, Y. Zhu, L. Gao, and S. Yang, “Load Adaptability of Active Harmonic Reduction for 12-Pulse Diode Bridge Rectifier With Active Interphase Reactor,” IEEE Trans. Power Electron., vol. 30, no. 12, pp. 7170–7180, Dec. 2015, doi: 10.1109/TPEL.2015.2391272.

H. Akagi and K. Isozaki, “A Hybrid Active Filter for a Three-Phase 12-Pulse Diode Rectifier Used as the Front End of a Medium-Voltage Motor Drive,” IEEE Trans. Power Electron., vol. 27, no. 1, pp. 69–77, Jan. 2012, doi: 10.1109/TPEL.2011.2157977.

R. C. Fernandes, P. da Silva Oliveira, and F. J. M. de Seixas, “A Family of Autoconnected Transformers for 12- and 18-Pulse Converters—Generalization for Delta and Wye Topologies,” IEEE Trans. Power Electron., vol. 26, no. 7, pp. 2065–2078, Jul. 2011, doi: 10.1109/TPEL.2010.2102773.

“IEEE Standard for Uncontrolled Traction Power Rectifiers for Substation Applications Up to 1500 V DC Nominal Output,” IEEE. doi: 10.1109/IEEESTD.2009.5398723.

P. Pozzobon, “Transient and steady-state short-circuit currents in rectifiers for DC traction supply,” IEEE Trans. Veh. Technol., vol. 47, no. 4, pp. 1390–1404, Nov. 1998, doi: 10.1109/25.728534.

J. Solanki, N. Frohleke, and J. Bocker, “Implementation of Hybrid Filter for 12-Pulse Thyristor Rectifier Supplying High-Current Variable-Voltage DC Load,” IEEE Trans. Ind. Electron., vol. 62, no. 8, pp. 4691–4701, Aug. 2015, doi: 10.1109/TIE.2015.2393833.

F. Meng, X. Xu, and L. Gao, “A Simple Harmonic Reduction Method in Multipulse Rectifier Using Passive Devices,” IEEE Trans. Ind. Inform., vol. 13, no. 5, pp. 2680–2692, Oct. 2017, doi: 10.1109/TII.2017.2723602.

J. Kim and J.-S. Lai, “Analysis of a Shunt Wye–Delta Transformer for Multi-Generator Harmonic Elimination Under Non-Ideal Phase-Shift Conditions,” IEEE Trans. Ind. Appl., vol. 55, no. 3, pp. 2412–2420, May 2019, doi: 10.1109/TIA.2019.2897319.

F. Meng, L. Gao, W. Yang, and S. Yang, “Comprehensive comparison of the delta- and wye-connected autotransformer applied to 12-pulse rectifier,” J. Mod. Power Syst. Clean Energy, vol. 4, no. 1, pp. 135–145, Jan. 2016, doi: 10.1007/s40565-016-0186-7.